Background
Detection and risk stratification of pulmonary nodules during a Lung Cancer Screening (LCS) examination is time-consuming, prone to false positives and missed detections. Leveraging Artificial Intelligence (AI) in such tasks has outperformed human readers in detection, and current risk models (Brock, MAYO) in risk prediction. Here, we present the results of an independent verification study to explore the software’s detection and characterization performance on an external dataset.
Methods
The model was trained on 10,872 patients (543 cancers) independently annotated from the NLST (National Lung Screening Trial) and LIDC (Lung Image Database Consortium) cohorts. 264 patients meeting the USPSTF criteria (age 50-80, Smoker) were collected from the EU (26%) and the USA (74%) for independent verification. The dataset comprised 88 cancer patients and 176 benign, with average size for all nodules of 6.2 ± 3.2 mm, and 17.5 ± 5.8 mm for cancerous nodules. To generate reference standards, two radiologists independently annotated each patient, with a third acting as an adjudicator to arrive at a consensus for location and nodule diagnosis (histopathology or ≥12 month stability).
Results
The verification AUC for risk prediction was 0.95, with a sensitivity of 93.2% and specificity of 87.5% at the Youden index. Cancer detection sensitivity was 91.2%, with an average of 0.44 false positive detections per scan. Performances were consistent across multiple technical and clinical parameters, including CT manufacturer, kernel hardness, kernel slice thickness, patient sex, data source, and nodule solidity (see the table). Table: 1192P
Subclass type | Subclass | AUC |
Manufacturer | SIEMENS Healthineers | 0.96 |
GE Healthcare | 0.94 | |
Canon/Toshiba | 0.95 | |
Kernel | Sharp | 0.98 |
Average | 0.94 | |
Soft | 0.93 | |
Slice thickness (mm) | 0.5-0.75 | 0.96 |
1-1.25 | 0.94 | |
1.25-1.5 | 0.96 | |
Sex | Female | 0.95 |
Male | 0.95 | |
Source | EU | 0.90 |
USA | 0.97 | |
Nodule solidity | Solid | 0.96 |
Part-solid | 0.93 |
Conclusions
This study demonstrates that the AI software is robust to external data with similar performances versus the NLST test set (AUC: 0.97) and among subclasses. More accurate screening driven by AI promises to be beneficial to LCS, reducing unneeded exams, costs, and radiologist time.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
Median Technologies.
Funding
Median Technologies.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
825P - Ultra-sensitive cfDNA analysis for minimally invasive measurable residual disease detection and profiling in multiple myeloma
Presenter: Natalia Buenache
Session: Poster session 09
826P - Efficacy of non-doxorubicin based regimens in severely G6PD deficient patients with DLBCL
Presenter: Shruti Prem Sudha
Session: Poster session 09
827P - Comparison of efficacy and safety between glofitamab and real-world regimens among Chinese patients with 3L+ relapsed/refractory diffuse large B-cell lymphoma: An external control study
Presenter: Keshu Zhou
Session: Poster session 09
828P - Translocation 11;14 is not associated with adverse prognosis in the era of novel anti-myeloma therapeutics
Presenter: Ioannis Ntanasis-Stathopoulos
Session: Poster session 09
829P - Flumatinib combined with chemotherapy for newly diagnosed adult with Ph-positive acute lymphoblastic leukemia: A single-center, retrospective observational study
Presenter: HAN SHUYU
Session: Poster session 09
830P - Prognostic model of pediatric AML patients with RUNX1-RUNX1T1 fusion gene
Presenter: Yang Xun
Session: Poster session 09
Resources:
Abstract
831P - Impact of chronic kidney disease on disease outcomes in hospitalized multiple myeloma patients: A National inpatient sample study from 2016 to 2020
Presenter: Marco Bermudez
Session: Poster session 09
Resources:
Abstract
832P - CLOMB: A validated scoring model to predict the relapse in the central nervous system of pediatric acute B-cell lymphoblastic leukemia
Presenter: Jiacheng Li
Session: Poster session 09
Resources:
Abstract
833P - Latest results of GVM±R regimen for the salvage therapy of patients with relapsed or refractory aggressive non-Hodgkin's lymphoma
Presenter: Wei Liu
Session: Poster session 09
834P - Treatment of DLBCL in HIV patient: Still a dilemma
Presenter: Devashish Desai
Session: Poster session 09