Abstract 175P
Background
Ki67 is an important BC marker, especially for adjuvant treatment in HR+, HER2- cases. Working groups have provided guidance for Ki67 immunohistochemistry (IHC) BC scoring to limit pathologist’s variability, but no scoring method has been universally accepted. Rapid and reliable image analysis solutions to support scoring have surfaced for the Ki67 assessment. We compared Ki67 scoring with Aiforia® Platform (AI deep learning image analysis), Halo® (image analysis supervised software) and 2 independent pathologists (patho) in a BC population.
Methods
We stained 114 BC tumors for Ki67 on the Dako Omnis. Three methodologies were used to quantify ki67+ tumor cells: 1) A deep learning approach model was trained for BC and the Ki67 clone by Aiforia; 2) Two pathos (Patho A and Patho B) were trained following the International Ki67 Working Group guidelines. Intra-analysis assessment was done for one patho; 3) The random forest classifier from Halo was used to separate the image into tumor, non-tumor and background with patho approval. After cell segmentation, Ki67 positivity was assessed by thresholding. The time needed to complete the analyses was recorded for each method.
Results
Intra-pathologist analysis showed a very high reproducibility (r2=0.95) while matched pair analysis between two patho was lower (r2=0.86) despite following guidelines. Our study shows a high consistency of Ki67 results between AI and the other methods (patho A-AI, r2=0.92; B-AI, r2=0.90; Halo-AI, r2=0.93). The correlation obtained between Halo scoring was not as good, but within an acceptable range (Halo-A, r2=0.79, Halo-B, r2=0.84). The deep learning AI approach was the quickest even including the model training (total time: 2.5 hrs). Pathos time ranged from 22 to 28 hrs without a major gain in analysis time in the second review. Halo took 28 hours including application development, pathologist verification, and analysis.
Conclusions
Overall, the ki67 tumor analysis approaches were quite comparable. AI-based image analysis tools offer valuable assistance in Ki67 scoring and could reduce inter-pathologist variability. These results demonstrate the time benefit of using an AI-driven method for Ki67 analysis in breast cancer.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
The authors.
Funding
Has not received any funding.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
172P - HER2 expression across solid tumors and real-world implications for use of fam-trastuzumab deruxtecan-nxki (T-Dxd)
Presenter: Ahmed Ismail
Session: Poster session 08
173P - Unveiling a novel EpCAM-CD24+ circulating cells with unidentified origin associated with breast cancer distant metastasis
Presenter: Evgeniya Grigoryeva
Session: Poster session 08
174P - Prognostic value of the immune and metabolic profile in the response to neoadjuvant treatment with ICIs in triple-negative breast cancer patients (TNBC)
Presenter: Lucía Serrano García
Session: Poster session 08
176P - ERBB2 amplifications across sex, race, and cancer types
Presenter: Marc Machaalani
Session: Poster session 08
177P - HER2 testing in multiple solid tumors: Concordance between 3 scoring algorithms
Presenter: Wentao Yang
Session: Poster session 08
178P - PD-L1 expression in ER-low versus triple-negative (TN) advanced breast cancer (aBC), and according to phenotypic evolution from primary to recurrent disease
Presenter: Federica Miglietta
Session: Poster session 08
179P - Multimodal deep learning integrating MRI and molecular profiles for predicting outcomes in triple-negative breast cancer
Presenter: Seong Hwan Park
Session: Poster session 08
181P - Molecular characterization and immune microenvironment analysis of MSI-H patients with or without MMR gene mutations
Presenter: Mengxi Ge
Session: Poster session 08
182P - Multi-modal artificial intelligence outperforms image-based approaches for mutation prediction from H&E tissue images in colorectal cancer
Presenter: Marc Päpper
Session: Poster session 08