Abstract 3517
Background
The role of FDG-PET/CT in the FU of LA-HNSCC is unclear.
Methods
Scan reports of LA-HNSCC patients, having FU-FDG-PET/CT performed 6-18 months after ST/CRT were retrospectively analyzed. Equivocal reports were scored as positive. Excluded were patients with proven recurrence before FU-FDG-PET/CT. The reference standard was the occurrence of a second primary (SP) or a recurrence < 12 months after FU-FDG-PET/CT. Primary endpoints included sensitivity, specificity, positive (PPV) and negative predictive value (NPV) on a patient level.
Results
We identified 73 patients. Primary tumor site: oropharynx: n = 35; 7 larynx: n = 7; hypopharynx: n = 11; oral cavity: n = 4; paranasal sinus: n = 4; unknown: n = 5. Tumor stage (UICC 7): II (T2N0): n = 1; III: n = 9; IV: n = 63. T1: n = 8; T2: n = 20; T3: n = 16; T4: n = 24. N0: n = 10; N1: n = 7; N2: n = 53; N3: n = 2. Patients were treated by CRT (n = 29) or ST (n = 44). A prior FDG-PET/CT at 3 months after end of treatment (EOT) (EOT-FDG-PET/CT) had been performed in 69/73 (60 negative, 6 false and 3 true positive [resected lymph nodes]). FU-FDG-PET/CT in patients without EOT-FDG-PET/CT was true negative in 3 patients and true positive in 1. Median time between EOT and FU-FDG-PET/CT was 12 months (range 6-17). Median FU after FU-FDG-PET/CT was 48 months (range 2-130). Sensitivity, specificity, PPV and NPV were 83% (95% CI 52-98), 87% (95% CI 76-94), 56% (95% CI 31-78) and 96% (95% CI 87-100), respectively. Local recurrences, SP and distant metastases were detected in 5, 1, and 4 patients, respectively. One FU-FDG-PET/CT-detected local recurrence and 1 SP were treated with curative intent. All false-positive patients (n = 8) underwent biopsy (n = 3) or surgery (n = 5). 15 patients (21%) recurred > 12 months after FU-FDG-PET-CT. Median overall survival was 49 (95% CI 29 - 68) and 98 months (95% CI 86-111) in FU-FDG-PET/CT-positive and -negative patients, respectively (p = 0.000196).
Conclusions
FU-FDG-PET/CT in real-life has a high NPV and significant prognostic value. However, false-positive scans induce invasive procedures in a significant fraction of patients.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
The authors.
Funding
Has not received any funding.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
5517 - Molecular fingerprinting in breast cancer (BC) screening using Quantum Optics (QO) technology combined with an artificial intelligence (AI) approach applying the concept of “molecular profiles at n variables (MPnV)”: a prospective pilot study.
Presenter: Jean-Marc Nabholtz
Session: Poster Display session 3
Resources:
Abstract
2152 - Inferring the correlation between incidence rates of melanoma and the average tumor-specific epitope binding ability of HLA class I molecules in different populations
Presenter: Istvan Miklos
Session: Poster Display session 3
Resources:
Abstract
4382 - Thermal Liquid Biopsy as a Valuable Tool in Lung Cancer Screening Programs
Presenter: Alberto Rodrigo
Session: Poster Display session 3
Resources:
Abstract
2465 - Towards a screening test for cancer by circulating DNA analysis
Presenter: Rita Tanos
Session: Poster Display session 3
Resources:
Abstract
3788 - Evaluation of a successful launch of the MammaPrint and BluePrint NGS kit
Presenter: Leonie Delahaye
Session: Poster Display session 3
Resources:
Abstract
3863 - Analysis of prognostic factors on overall survival in elderly women treated for early breast cancer using data mining and machine learning
Presenter: Pierre Heudel
Session: Poster Display session 3
Resources:
Abstract
1993 - Circulating tumor cell detection in epithelial ovarian cancer using dual-component antibodies targeting EpCAM and FRα
Presenter: Na Li
Session: Poster Display session 3
Resources:
Abstract
4281 - CEUS of the breast: Is it feasible in improved performance of BI-RADS evaluation of critical breast lesions?——A multi-center prospective study in China
Presenter: Jun Luo
Session: Poster Display session 3
Resources:
Abstract
2268 - Classification of abnormal findings on ring-type dedicated breast PET for detecting breast cancer
Presenter: Shinsuke Sasada
Session: Poster Display session 3
Resources:
Abstract
4035 - Prediction of benign and malignant breast masses using digital mammograms texture features
Presenter: Cui Yanhua
Session: Poster Display session 3
Resources:
Abstract