Abstract 4787
Background
Comparison of options from clinical decision-support (CDS) systems and decisions made in practice may be biased towards the treating institution. In this retrospective study, bias was minimized by blinding evaluators to the source of treatment recommendations, either Watson for Oncology® (WFO®) or treatments patients received at Bumrungrad International Hospital (BIH), a user of WFO®.
Methods
Treatments given were compared to therapeutic options provided by WFO®. Treatments that were identical to WFO® “recommended” (green, acceptable) were not evaluated further. Paired treatments were evaluated independently in a blinded fashion by each oncologist before consensus ranking of each pair as either acceptable, acceptable alternatives, or unacceptable treatment. The consensus for each treatment was compared to WFO®, with WFO® “for consideration” (yellow, acceptable alternative), and “not recommended” (red, unacceptable). Chi-squared tests analyzed the association between risk factors and discordant recommendations.
Results
Of 228 treatments given to patients with lung, colon, breast and rectal cancers, 174 were identical to WFO® acceptable (green) and not evaluated further; 54 non-identical pairs were evaluated (Table). Overall, 88.6% of decisions were either the same or viewed as equally acceptable by oncologists; oncologists preferred 3.9% of BIH treatments and 4.4% of WFO treatments. In cases where reasons for discordance were provided, 70% were due to BIH oncologist preference, 20% to patient preference and 10% to WFO treatment availability. We found no association between discordant recommendations and patient age or stage of cancer.Table: 1435P
Treatments | N (%) 228 Total |
---|---|
Treatments are identical | 174 (76.3%) |
Oncologists’ Evaluations | |
Acceptable alternatives | 28 (12.3%) |
BIH Preferred | 9 (3.9%) |
WFO Preferred | 10 (4.4%) |
Both WFO and BIH-Rx unacceptable | 7 (3.1%) |
Conclusions
This blinded study suggests WFO®’s therapeutic options are at as least as good as (or are an acceptable alternative to) treatments in practice. Blinding evaluators to source of treatment may minimize bias in comparisons of CDS systems and decisions made in practice.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
Bumrungrad International Hospital.
Funding
Bumrungrad International Hospital.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
5517 - Molecular fingerprinting in breast cancer (BC) screening using Quantum Optics (QO) technology combined with an artificial intelligence (AI) approach applying the concept of “molecular profiles at n variables (MPnV)”: a prospective pilot study.
Presenter: Jean-Marc Nabholtz
Session: Poster Display session 3
Resources:
Abstract
2152 - Inferring the correlation between incidence rates of melanoma and the average tumor-specific epitope binding ability of HLA class I molecules in different populations
Presenter: Istvan Miklos
Session: Poster Display session 3
Resources:
Abstract
4382 - Thermal Liquid Biopsy as a Valuable Tool in Lung Cancer Screening Programs
Presenter: Alberto Rodrigo
Session: Poster Display session 3
Resources:
Abstract
2465 - Towards a screening test for cancer by circulating DNA analysis
Presenter: Rita Tanos
Session: Poster Display session 3
Resources:
Abstract
3788 - Evaluation of a successful launch of the MammaPrint and BluePrint NGS kit
Presenter: Leonie Delahaye
Session: Poster Display session 3
Resources:
Abstract
3863 - Analysis of prognostic factors on overall survival in elderly women treated for early breast cancer using data mining and machine learning
Presenter: Pierre Heudel
Session: Poster Display session 3
Resources:
Abstract
1993 - Circulating tumor cell detection in epithelial ovarian cancer using dual-component antibodies targeting EpCAM and FRα
Presenter: Na Li
Session: Poster Display session 3
Resources:
Abstract
4281 - CEUS of the breast: Is it feasible in improved performance of BI-RADS evaluation of critical breast lesions?——A multi-center prospective study in China
Presenter: Jun Luo
Session: Poster Display session 3
Resources:
Abstract
2268 - Classification of abnormal findings on ring-type dedicated breast PET for detecting breast cancer
Presenter: Shinsuke Sasada
Session: Poster Display session 3
Resources:
Abstract
4035 - Prediction of benign and malignant breast masses using digital mammograms texture features
Presenter: Cui Yanhua
Session: Poster Display session 3
Resources:
Abstract