Oops, you're using an old version of your browser so some of the features on this page may not be displaying properly.

MINIMAL Requirements: Google Chrome 24+Mozilla Firefox 20+Internet Explorer 11Opera 15–18Apple Safari 7SeaMonkey 2.15-2.23

Poster Display session 2

5773 - A prospective study of diffusion-weighted magnetic resonance imaging for predicting outcome following chemoradiotherapy, in squamous cell carcinomas of the anus.

Date

29 Sep 2019

Session

Poster Display session 2

Topics

Tumour Site

Colon and Rectal Cancer

Presenters

Rebecca Muirhead

Citation

Annals of Oncology (2019) 30 (suppl_5): v198-v252. 10.1093/annonc/mdz246

Authors

R. Muirhead1, D. Bulte2, R. Cook3, K. Chu4, L. Durrant3, V. Goh5, C. Jacobs1, S.M. Ng6, V.Y. Strauss7, P.S. Virdee7, C. Qi7, M.A. Hawkins4

Author affiliations

  • 1 Department Of Oncology, Oxford University NHS Foundation Trust, OX37LE - Oxford/GB
  • 2 Institute Of Biomedical Engineering, University of Oxford, OX3 7LE - Oxford/GB
  • 3 Radiotherapy Department, Oxford University NHS Foundation Trust, OX3 7LE - Oxford/GB
  • 4 Cruk Mrc Oxford Institute For Radiation Oncology, University of Oxford, Oxford/GB
  • 5 Cancer Imaging, School Of Biomedical Engineering & Imaging Sciences,, King’s College London, WC2R 2LS - London/GB
  • 6 Oncology Clinical Trials Office, Department Of Oncology,, University of Oxford, OX3 7LE - Oxford/GB
  • 7 Centre For Statistics In Medicine, Ndorms, University of Oxford, OX3 7LE - Oxford/GB

Resources

Login to get immediate access to this content.

If you do not have an ESMO account, please create one for free.

Abstract 5773

Background

Anal Squamous Cell Carcinoma (ASCC) is radically treated by chemoradiotherapy (CRT). The use of DW-MRI as a predictive marker of outcome would enable early individualisation of treatment. We aimed to quantify the changes in mean apparent-diffusion-coefficient (ADCMean) between a DW-MRI at diagnosis and on fraction 8-10 of CRT as a biomarker for cellularity, and correlate these with outcome.

Methods

This prospective study recruited patients with ASCC between October 2014 and November 2017. DW-MRI was performed at diagnosis and after fraction 8-10 of radical CRT. A region of interest (ROI) was delineated for all primary tumours and any lymph nodes >2 cm on high-resolution T2 –weighted images and propagated to the ADC map. A pre-defined cut-off for percentage change in ADCMean (ΔADC) was set at < 20%. Complete response (CR) was assessed 3 months following completion of CRT. Routine clinical follow up data from patients were collected from NHS electronic systems.

Results

Twenty-three of 29 recruited patients underwent paired DW-MRI scans. The median (range) tumour volume was 13.6 cm3 (2.8 cm3 to 84.9 cm3). The median ΔADCMean between scans was 20.7% (95% CI: 12.7%, 34.1%). Nine of 23 (43%) patients had a change of ADCMean <20%. Two patients failed to achieve a CR, with ΔADCMean of 14.6% and 20.3%, respectively. On routine follow up, 2 further patients had relapsed, with ΔADCMean of -1.2% and 6.8%.

Conclusions

In a subset of patients, <20% ΔADCMean on DW-MRI between diagnosis and day 8-10 of CRT was observed. Four patients in the study demonstrated persistent or recurrent disease, all of whom demonstrated an ADC on or below the pre-specified cut-off. Further investigation of the predictive merit of DW-MRI change, and the optimum cut-off is needed in larger cohorts.

Clinical trial identification

NCT02145416.

Editorial acknowledgement

Legal entity responsible for the study

University of Oxford.

Funding

CRUK EPSRC Cancer Imaging Centre in Oxford, the CRUK Oxford Centre and the NIHR.M Hawkins is supported by Medical Research Council grant MC_UU_00001/2.

Disclosure

R. Muirhead: Honoraria (self), Fee for lecture: Boehringer Ingelheim. V. Goh: Research grant / Funding (self): Siemens. All other authors have declared no conflicts of interest.

This site uses cookies. Some of these cookies are essential, while others help us improve your experience by providing insights into how the site is being used.

For more detailed information on the cookies we use, please check our Privacy Policy.

Customise settings
  • Necessary cookies enable core functionality. The website cannot function properly without these cookies, and you can only disable them by changing your browser preferences.