Abstract 278P
Background
Radical chemoradiation (CTRT) is the standard of care in locally advanced head and neck cancer (LAHNC). For mitigating the normal tissue toxicity, many techniques have been explored and utilized, including IMRT and adaptive radiotherapy (ART). Significant anatomical variations occur during CTRT due to weight loss and tumor and normal tissue changes. In the present study, serial changes in parotid volumes were assessed with weekly scans along with dosimetric correlation.
Methods
This prospective, single-institutional study, included 12 patients with LA HNC receiving CTRT. All underwent CT simulation (CT sim) followed by weekly rescans from week 1 to 6. Target volumes and organs at risk, including right & left parotids (RP & LP) were recontoured in all rescans after fusion with the CT sim. Dose overlay was done in each rescan to generate a hybrid plan to study corresponding dosimetric variations. Volume changes in parotids were reported as percentage change from the baseline.
Results
In CT sim, right parotid volumes (RPV) ranged from 15.7 - 44.2 cc (mean - 24.1 SD – 7.9) and left parotid volume (LPV) from 12.2 - 47.1 cm3 (mean 22.8, SD -9.9). Mean % reduction in RPV in week 1, 2, 3, 4, 5 and 6 were 14.2% (p=0.003), 17.1% (p=0.007), 21.8% (p < 0.001), 25.6% (p < 0.001), 30% (p < 0.001), 32.1% (p < 0.001) respectively. Mean % reduction in LPV in week 1, 2, 3, 4, 5 and 6 were 8.9% (p=0.016), 14.5% (p=0.012), 17.7% (p=0.001), 20.1% (p=0.002), 24.9% (p < 0.001), 28.9% (p < 0.001) respectively. LP D mean showed a significant increase in week 3 (4.6% from baseline, p=0.019) and week 6 (7.6% from baseline, p=0.034). Both parotids showed a significant reduction in V26 Gy with 12.3%, 15.1%, 18.9%, 22.9%, 25.7%, 27.0%, respectively, from week 1 to 6 in RP and 7.3%, 15.7%, 13.8%, 16.8%, 20.8%, 24.1%, respectively, in LP.
Conclusions
Parotid volume shrinkage started from the 1st week. At the end of CTRT, there was 30-32% reduction in volume. V26 Gy of both parotids showed significant reduction during CTRT. Studies focusing on parotid volume changes shows wide variations in volume reduction ranging from 13% to 50% at the end of treatment. These parotid volume changes during RT need to be incorporated while doing ART in LAHNC.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
Uttarakhand.
Funding
Has not received any funding.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
313P - Diagnostic value of micro RNA (miRNA) in renal cell cancer: A meta-analysis and systemic review
Presenter: Jestoni Aranilla
Session: e-Poster Display Session
314P - Comprehensive microbial signatures and genomic profiling in tumour samples using next generation sequencing
Presenter: Mei Qi Yee
Session: e-Poster Display Session
315P - High-penetrance breast and/or ovarian cancer susceptibility genes in Filipinos
Presenter: Frances Victoria Que
Session: e-Poster Display Session
316P - Implementation of Vela Analytics to accelerate comprehensive interpretation and reporting of next-generation sequencing-based oncology testing in clinical diagnostic laboratories
Presenter: Yingnan Yu
Session: e-Poster Display Session
317P - Genomic profiling and molecular pathology of Chinese glioma patients
Presenter: yuanli Zhao
Session: e-Poster Display Session
320P - Psychometric interplay of the perception of the real-life impact of COVID-19 pandemic: A cross-sectional survey of patients with newly diagnosed malignancies
Presenter: Kelvin Bao
Session: e-Poster Display Session
321P - Impact of COVID-19 and lockdown on adherence to treatment schedule among cancer patients
Presenter: Krishnamani Kalpathi
Session: e-Poster Display Session
322P - Challenged faced by cancer patients during the COVID-19 pandemic
Presenter: mithra Krishnamani
Session: e-Poster Display Session
323P - Oncology care in the Republic of Kazakhstan during COVID-19
Presenter: Dilyara Kaidarova
Session: e-Poster Display Session
324P - COVID era: Perception of oncologists from a developing nation
Presenter: Rakesh Roy
Session: e-Poster Display Session