Poster Display session 2

2221 - Identification of ultralow risk breast cancer patients (probable overdiagnosis)

Date

29 Sep 2019

Session

Poster Display session 2

Topics

Tumour Site

Breast Cancer

Presenters

Salvador Gamez Casado

Citation

Annals of Oncology (2019) 30 (suppl_5): v55-v98. 10.1093/annonc/mdz240

Authors

S. Gamez Casado1, M. Bernal Gómez1, A. Campini Bermejo1, L. Rodriguez Perez2, A. Quilez2, J. Calvete Candenas2, G. Martínez Bernal3, E. Benítez Rodríguez4, J.M. Baena-Canada2

Author affiliations

  • 1 Medical Oncology, Hospital Universitario Puerta del Mar, 11009 - Cadiz/ES
  • 2 Medical Oncology, Hospital Puerta del Mar, 11009 - Cadiz/ES
  • 3 Medical Oncology, Hospital Virgen del Rocío, 41013 - Sevilla/ES
  • 4 Epidemiología, Registro Provincial del cáncer, Cádiz, 11009 - Cadiz/ES

Resources

Login to get immediate access to this content.

If you do not have an ESMO account, please create one for free.

Abstract 2221

Background

The universalisation of mammographic screening has caused an increase in ultralow risk breast cancer diagnosis. Identifying subgroups with no events related to mortality due to breast cancer in the long term (overdiagnosis) may be useful so as not to subject them to unnecessary treatment (overtreatment).

Methods

New ultralow risk criteria are described by means of mammographic screening diagnosis, tumour palpability, tumour phenotype, and absence of axillary node involvement. We identified patients with no events related to breast cancer mortality through a descriptive, observational, and retrospective study.

Results

Among the 746 patients with stage I and IIA breast cancer attended between 1/1/2001 and 31/12/2014, 110 (14.75%) came from mammographic screening with non-palpable tumours. The median age was 58 years old (38-71). 88 (80%) were hormone receptor positive (HR+), 10 (9.10%) were triple negatives, and 11 (10%) were HER-2. The median follow-up was 10 years (3.5-17). Only 3 patients developed metastasis, there were no loco-regional recurrence, 7 showed second primary tumours, and there were 4 deaths, 2 due to breast cancer and 2 due to other reasons. Overall survival (OS) was 92.80%, disease-free survival (DFS) was 85.20%, and the distant metastasis-free interval (DMFI) was 95.60%. In 88 patients with HR+ tumours, OS was 95.7%, DFS was 86.50%, and DMFI was 96.30%. In 34 (38.60%) histological grade 1 HR+ tumours (probably Luminal A), and in 54 (61.40%) histological grade 2-3 HR+ tumours (probably Luminal B), OS was 93.80% and 96.90% (p = 0.669), DFS was 81.90% and 89.30% (p = 0.400), and DMFI was 100% and 94.40% (p = 0.307). In triple negatives, OS was 85.70%, DFS 77.10%, and DMFI was 100%. In subgroup HER-2, there were no events. In tumours smaller and larger than 1 cm, OS was 100% and 90.20% (p = 0.168), DFS was 93.20% and 84.10% (p = 0.742), and DMFI was 100% and 95.50% (p = 0.296).

Conclusions

Patients with non-palpable tumours detected in mammographic screening have an ultralow risk. The absence of events related to breast cancer mortality makes them candidates for overdiagnosis. De-escalation of treatment should be considered. The authors will incorporate genomic risk to optimise the identification of overdiagnosis.

Clinical trial identification

Editorial acknowledgement

Legal entity responsible for the study

The authors.

Funding

Has not received any funding.

Disclosure

All authors have declared no conflicts of interest.

This site uses cookies. Some of these cookies are essential, while others help us improve your experience by providing insights into how the site is being used.

For more detailed information on the cookies we use, please check our Privacy Policy.

Customise settings
  • Necessary cookies enable core functionality. The website cannot function properly without these cookies, and you can only disable them by changing your browser preferences.