Abstract 424P
Background
Radiotherapy is a primary or an adjuvant treatment for most brain tumor patients for better tumors control and prolong survival [1]. However, cranial irradiation may cause damages to hippocampus (plural: hippocampi), which may induce dementia after they recovered from the disease [2]. To minimise radiation dose to hippocampus becomes a new trend in radiation therapy [3], [4]. This study is to investigate whether traditional coplanar VMAT (CO-VMAT) or proposed non-coplanar VMAT (NC-VMAT) is dosimetrically superior for brain tumor radiotherapy treatment in view of hippocampus sparing.
Methods
Both CO-VMAT plan and NC-VMAT plan were generated for 16 brain tumor patients (Glioblastoma: 11, Meningioma: 5) using Varian Eclipse planning system version 15.6. The prescription was to give 54 Gy to PTV in 30 fractions. Dose constraints applied for plan optimization were benchmarked against Radiation Therapy Oncology Group (RTOG). In the CO-VMAT plans, there were 1 full arc (179°-181°) and 2 half arcs. The couch angle for all arcs were 0°. For cases with PTV located at the left side of the brain, the gantry angle for the 2 half arcs were set from 0°to 179° and 179° to 0°. While for cases with PTV on the right side of the brain, the gantry angle of the 2 half arcs were set from 0° to 181°and 181°to 0°. In the NC-VMAT plans, all setting were the same as CO-VMAT plans, except that the couch angle for the 2 half arcs was at 315° for PTV located at the left side of the brain, and 45° for PTV located on the right side of the brain.
Results
Homogeneity index, conformation number, dose to other organs at risk and ipsilateral hippocampus were similar in CO-VMAT and NC-VMAT plans. The maximum dose (D-MaxCH) received by contralateral hippocampus in NC-VMAT is 4Gy lower (p=0.049) than that of the CO-VMAT. The dose received by 40 % of the contralateral hippocampus (D40%CH) in NC-VMAT is 1.46Gy (p=0.003) lower than that of the CO-VMAT. The mean D-MaxCH and mean D40%CH were reduced by 23% and 23.5% respectively in NC-VMAT plans when compared with CO-VMAT.
Conclusions
The NC-VMAT is able to minimize radiation dose to contralateral hippocampus while maintaining good plan quality. The NC-VMAT approach may help to consolidate the development of a new standard of care for brain tumor patients.
Clinical trial identification
Editorial acknowledgement
Legal entity responsible for the study
Tung Wah College.
Funding
Has not received any funding.
Disclosure
All authors have declared no conflicts of interest.
Resources from the same session
402P - Efficacy and safety of sintilimab plus docetaxel in patients with previously treated advanced non-small cell lung cancer (NSCLC)
Presenter: Zhehai Wang
Session: e-Poster Display Session
403P - Clinical profile, practice pattern and outcomes in ALK-positive lung cancer: Real-world data from India
Presenter: Akhil Kapoor
Session: e-Poster Display Session
404P - Financial toxicity in patients with advanced lung cancer treated with immunotherapy: Has it an effect on the clinical decision?
Presenter: Jia-Hui Weng
Session: e-Poster Display Session
405P - Promising efficacy as combination therapy of DFP-14323, protease inhibitor, with EGFR-TKI in patients with metastatic NSCLC harboring EGFR mutation
Presenter: Hiroshige Yoshioka
Session: e-Poster Display Session
406P - Anti-PD-1 versus anti-PD-L1 inhibitors in first-line therapy non-small-cell lung cancer: A systematic review and meta-analysis
Presenter: Angelo Brito
Session: e-Poster Display Session
407P - Integrating histologic and genomic characteristics to predict tumour mutation burden of early-stage non-small cell lung cancer
Presenter: Yuan Qiu
Session: e-Poster Display Session
408P - Integrated chemotherapy with EGFR receptor tyrosine kinase inhibitors in patients with non-small cell lung cancer harboring EGFR mutation
Presenter: Julia Maevskaya
Session: e-Poster Display Session
409P - Effect of transdermal granisetron on prevention of nausea and vomiting during chemotherapy of lung cancer
Presenter: Haifeng Qin
Session: e-Poster Display Session
410P - Frequency and spectrum of primary resistance mechanism in Chinese ALK+ non-small cell lung cancer patients progressing on crizotinib: A multicenter study
Presenter: Wen-xian Wang
Session: e-Poster Display Session
411P - Impact of pre-treatment AXL expression on osimertinib efficacy in patients with non-small cell lung cancer with EGFR mutation
Presenter: Yoshihiko Taniguchi
Session: e-Poster Display Session